Why does Boilers main steam temperature increase more than design?

 1-Decrease in Economiser inlet feed water temperature

Upon decrease in economiser inlet feed water temperature, fuel consumption in furnace increases & hence main steam temperature increases more than desired.

2-Load on Boilers is more than design

Main steam temperature increases if the steam generation is more than actual designed

3-Leakage in super heater (SH) coils



If there is any leakages in SH coils, steam flow to SH coil decreases & hence main steam temperature increases.

4-Choking in Super heater coils




Super heater coils Choking due to foreign materials & internal scaling due to poor water chemistry leads to less steam flow through coils resulting into higher main steam temperature due to poor heat transfer.

5-Passing of start-up vent control valve

Passing of start-up control valve loads more on Boiler steam generation, hence main steam temperature increases

6-Passing or pop up of drum safety valves : Lifting of drum safety valves lead to less steam flow to SH coils resulting into higher main steam temperature.

7-High moisture fuel: If the fuel moisture is more than required, then water present in the fuel absorbs heat from furnace & transfer heat convectively to SH coil.





8-Low GCV fuel: Burning of low GCV coal in furnace releases more heat & hence MS temperature increases.

Note: Burning of high GCV fuel with high moisture also leads to temperature shoot-up.

9-Failure of attemperator control system or wrongly tuned attemperator control valves.



10-Operating the Boilers at more negative draught: This causes more convection heat transfer in SH, (& also at economizers & APH) leading into high main steam temperature

11-More excess air also can lead to fast heat transfer, which can result into high main steam temperature

12-Wrongly designed SH coils: If there is provision of more heating surface in SH coils, then eventually steam temperature always maintains on higher side.

13-Very Clean & scale free surface of SH coils: Leads to faster heat transfer in SH zones causing more steam temperature

14-High moisture content combustion air leads to increase in MS temperature

15-Lesser turbulence in furnace leads more convective heat transfer at SH zone & eventually results high main steam temperature.

16-Wrongly designed SH & furnace zone: High velocity of FG in furnace & SH zone leads to fast heat transfer, this causes high main steam temperature.

17-Mixing of fuels in furnace: Causes uncontrolled excess air & draught which causes main temperature to increase.


Read related articles

1-Objective QNA for BOE exam preparation

2-Boiler calculations for BOE exam

3-Factors considered for Boiler design & engineering

4-Procedure (SOP) for Boiler gauge glass line up


Acer Nitro 5 Intel Core i5-10th Gen 15.6-inch Display Thin and Light Gaming Laptop (8GB Ram/1TB HDD + 256GB SSD/Win10/GTX 1650Ti Graphics/Obsidian Black/2.3...

BUY NOW

Tolsen V80115-15PCS Insulated Set - VDE 1000 Volts

                                                                            BUY NOW

Visit the website www.powerplantandcalculations.com

2 comments:

Hi all,
This article is written based on practical experience..If liked, share with others, or any suggestions leave in comment box.

Online calculation of centrifugal pump power

 How do you calculate the Hydraulic power, shaft power and motor power of a centrifugal pumps? I nputs needed: Pump flow Pump suction lift a...