Saturday, 15 November 2025

Desuper heating water flow online calculator

 









What is Desuperheating?

Desuperheating (or attemperation) is the process of reducing the temperature of super heated steam by injecting water. The injected water absorbs heat from the steam and evaporates completely, bringing the steam temperature closer to saturation or the specified outlet temperature.

Typical applications:

  • Boiler outlet temperature control

  • Turbine inlet temperature control

  • HRSG and WHRB steam temperature regulation

  • Process steam conditioning

Parameters Required for Calculating Desuperheating Water Flow

To determine the required spray water quantity, you need:

Steam Input Conditions

  • Inlet steam pressure (P₁)

  • Inlet steam temperature (T₁)

Steam Output Requirements

  • Outlet steam pressure (P₂)

  • Outlet steam temperature (T₂)

Water Conditions

  • Desuperheating water temperature (Tᵥ)

Desuper heating water flow online calculator
Desuperheating Water Quantity Calculator

Desuperheating Water Quantity Calculator

Calculates spray water required based on inlet & outlet steam pressure/temperature and water temperature.

No comments:

Post a Comment

Hi all,
This article is written based on practical experience..If liked, share with others, or any suggestions leave in comment box.

Online calculation of centrifugal pump power