APH is an auxiliary used in steam generators or boilers to
increase the Boiler efficiency and to reduce the fuel consumption.
There are different types of air heaters. Major types are tubular & regenerative air preheater.
These may be installed horizontally
or vertically as per requirement.
In some design of APH air flows outside
the tubes and flue gas inside the tubes where as in some cases air flows inside
the tubes and flue gas outside of the tubes.
The main functions of APH is to
reduce the flue gas temperature to allowable limit that is coming out from
Boiler and to increase combustion air temperature.
The efficiency of the APH are
calculated from two ways one is from air side other from gas side.
APH gas side efficiency
ηAPHg = (Flue gas inlet temp.Tfi-Flue gas
outlet temp.Tfo) X 100 / (Flue gas inlet temperature tfi-Air inlet temperature
Tai)
APH air side efficiency
ηAPHa = (Air outlet temp.Tao-Air inlet
temp.Tao)) X 100 / (Flue gas inlet temperature tfi-Air inlet temperature Tai)
Calculate the APH gas side & air efficiency if
its flue gas inlet and out let temperature are 230 deg C and 145 deg C and air
inlet and out let temperatures are 28 deg C & 180 deg C respectively.
ηAPHg = (Flue gas inlet temp.Tfi-Flue gas
outlet temp.Tfo) X 100 / (Flue gas inlet temperature tfi-Air inlet temperature
Tai)
ηAPHg =(230-145) X 100 / (230-28)
ηAPHg = 42.1%
ηAPHa = (Air outlet temp.Tao-Air inlet
temp.Tao)) X 100 / (Flue gas inlet temperature tfi-Air inlet temperature Tai)
ηAPHa = (180-28) X 100 / (230-28)
ηAPHa = 75.24%
Read Economiser efficiency calculation
A Tubular type APH is having air side efficiency
79%, its flue gas and air inlet temperature are 225 deg and 30 deg C
respectively, calculate the APH outlet air temperature
We have,
ηAPHa = (Air outlet temp.Tao-Air inlet
temp.Tao)) X 100 / (Flue gas inlet temperature tfi-Air inlet temperature Tai)
79% = (Tao-30) X 100 / (225 – 30)
Tao-30 = 0.79 X 195
Tao = 184.05 deg C
A Tubular type APH is having gas side efficiency 39%,
its flue gas and air inlet temperature are 225 deg and 30 deg C respectively,
calculate the APH outlet flue gas temperature
We have,
ηAPHg = (Flue gas inlet temp.Tfi-Flue gas
outlet temp.Tfo) X 100 / (Flue gas inlet temperature tfi-Air inlet temperature
Tai)
39% = (225-Tfo) X 100 / (225-30)
0.39 X 195 = 225-Tfo
Tfo = 148.95 deg C