The efficiency of the APH are calculated from two
ways one is from air side other from gas side.
APH gas side efficiency
ηAPHg = (Flue gas inlet temp.Tfi-Flue gas outlet
temp.Tfo) X 100 / (Flue gas inlet temperature tfi-Air inlet temperature Tai)
APH air side efficiency
ηAPHa = (Air outlet temp.Tao-Air inlet temp.Tao)) X
100 / (Flue gas inlet temperature tfi-Air inlet temperature Tai)
Calculate the APH gas
side & air efficiency if its flue gas inlet and out let temperature are 245
deg C and 155 deg C and air inlet and out let temperatures are 32 deg C & 173
deg C respectively.
APH Gas side
efficiency calculation
ηAPHg = (Flue gas inlet temp.Tfi-Flue gas outlet
temp.Tfo) X 100 / (Flue gas inlet temperature tfi-Air inlet temperature Tai)
ηAPHg =(245-155) X 100 / (245-32)
ηAPHg = 42.25%
APH Air side
efficiency calculation
ηAPHa = (Air outlet temp.Tao-Air inlet temp.Tao)) X
100 / (Flue gas inlet temperature tfi-Air inlet temperature Tai)
ηAPHa = (173-32) X 100 / (245-32)
ηAPHa = 66.19%