Economiser
efficiency is calculated as below.
ηEco. = (Economiser outlet feed water temperature Two-Economiser
inlet feed water temperature Twi) X 100 / (Economiser inlet flue gas
temperature Tfi- Economiser inlet feed water temperature Twi)
Example:
Calculate the economiser effectiveness,
whose feed water inlet & outlet temperatures are 150 Deg C & 220 Deg C
respectively & flue gas inlet & outlet temperatures 385 deg C & 215
deg c respectively.
Solution:
Twi = 150 deg C
Two = 220 deg C
Tfi = 385 deg C
Tfo = 215 deg C
ηEco = (Two-Twi) X 100 / (Tfi-Twi)
ηEco = (220-150 ) X 100 / (385-150)
ηEco= 29.78%
Boiler Economiser Efficiency Calculator
Enter all temperatures in degree Celsius (°C)